KSH-018-0001

Thermostatic Mixing Valves

Thermostatic Tempering Valves for Individual Lavatory Installations.


DESCRIPTION

The KSH-018-0001 thermostatic mixing valves maintain and limit hot water to desired selectable temperature between 80°F and 120°F (27°C and 49°C) with flow rates as low as 0.25 gpm (1.0 lpm) and as high as 2.25 gpm (8.5 lpm). The mixing valve is listed to ASSE 1070 for single fixture applications and IAPMO cUPC.

The KSH-018-0001 features a rapid response thermostatic element for superior control. The thermostatic element senses the outlet water temperature and reacts to maintain a constant delivery temperature even under changing flows or variations in supply temperatures or pressures. It provides stable operation at flow rates as low as 0.25 gpm (1.0 lpm). The valve also reduces the outlet flow to a trickle in the event of a cold water supply failure.

The KSH-018-0001 has inlet a compression connection to 3/8" OD tube. Also available with cold water bypass. Supplied standard with integral check valves on both inlets to prevent cross-flow. 

  Temperature Adjustment   80 – 120°F (27 – 49°C)
  Maximum Supply Pressure           200 psi (1379 kPa)
  Temp. hot supply   120 – 180°F (49 – 82°C)
  Temp. cold supply   39 – 80°F (4 – 27°C)
  Minimum Flow   0.25 gpm (1.0 lpm)
  Listing   ASSE-1070, IAPMO cUPC, and NSF 61 & 372